Search results for "width [Lambda(1405)]"

showing 10 items of 330 documents

High power analysis and design of dual-mode channel filters

2009

In this paper, we present two dual-mode channel filter topologies which are able to withstand more than 600 W in Ku-Band. The two different designs (one with elliptical cavities and the other one with rectangular cavities) implement the same transfer function: four order, elliptical response centered in 12 GHz, with 40 MHz bandwidth and two transmission zeros. It is shown that the critical dimensions for the power-handling of these filters are the dimensions of the input-output irises. In fact, in order to rigorously obtain these conclusions and to reach these high-power levels (including margins), it is essential to use the advanced numerical techniques described in the paper to predict th…

Multipactor effectEngineeringWaveguide filterbusiness.industryBandwidth (signal processing)Electronic engineeringPole–zero plotbusinessNetwork topologyKu bandTransfer functionVoltage2009 IEEE MTT-S International Microwave Symposium Digest
researchProduct

Bandwidth Resource Management for Neural Signal Telemetry

2009

Recent advances in modern neurocomputing have shown the utmost necessity of wireless communication systems that allow real-time (RT) monitoring of neural signals meeting several requirements such as source compression and high fidelity of the received signal. Neural recordings require multielectrode probes with up to hundreds of electrodes and transmission of signals wirelessly over a limited bandwidth (BW). In this paper, a RT resource management algorithm is proposed so that adequate source compression is applied to each channel in order to fit them into the available BW. Performance of the algorithm is analyzed using dynamically changing BW and neural recordings with different neural act…

NeuronsComputer scienceModels NeurologicalReal-time computingSignal Processing Computer-AssistedGeneral MedicineSignalRatsComputer Science ApplicationsBandwidth allocationTransmission (telecommunications)Bandwidth (computing)AnimalsTelemetryResource allocationAlgorithm designElectrical and Electronic EngineeringAlgorithmsCells CulturedMonitoring PhysiologicBiotechnologyData compressionCommunication channelIEEE Transactions on Information Technology in Biomedicine
researchProduct

HF Noise Measurements Based on Software Defined Radio Dual Receiver and Two Orthogonal Inverted Vee Antennas

2020

Increasing the data transfer rate in the High Frequency (HF) range involves enlarging the bandwidth of the channel from the standard value of 3 kHz to values of 6, 12, 24, 48 and even 96 kHz. Real-time evaluation of the noise power in the channel under such conditions is essential. This paper aims to implement an automated system for real-time measurement of noise in the HF range. It is composed of two Software Defined Radio (SDR) synchronized receivers and two orthogonal Inverted Vee antennas. Testing the system demonstrates its ability to distinguish between noise and signals generated as a result of human activity. Preliminary results of measurements performed in an urban location are co…

Noise powerNoise measurementComputer sciencebusiness.industry020209 energyAcoustics020208 electrical & electronic engineeringBandwidth (signal processing)02 engineering and technologySoftware-defined radioNoise (electronics)Software0202 electrical engineering electronic engineering information engineeringbusinessCommunication channelData rate units2020 International Conference and Exposition on Electrical And Power Engineering (EPE)
researchProduct

Nuclear physics with ion traps at ISOLDE: present and future

1993

Nuclear physics experiments with ion traps started at the on-line separator ISOLDE/CERN, Geneva, with the installation of the tandem Penning trap mass spectrometer ISOLTRAP. With this device the massM of a stored ion is determined by measuring its cyclotron frequency θc=(q/M)B in a magnetic fieldB. Mass measurements with a resolving powerR=θc/Δθc(FWHM)≈1×106 and accuracies of δM/M≈10−7 were performed on more than sixty unstable isotopes of the elements Rb, Sr, Cs, Ba, Fr, and Ra.

Nuclear and High Energy PhysicsLarge Hadron ColliderIsotopeChemistryCyclotronCondensed Matter PhysicsPenning trapMass spectrometryISOLTRAPAtomic and Molecular Physics and Opticslaw.inventionIonNuclear physicsFull width at half maximumlawPhysical and Theoretical ChemistryAtomic physicsHyperfine Interactions
researchProduct

Recent advances in the development of high-resolution 3D cadmium-zinc-telluride drift strip detectors.

2020

In the last two decades, great efforts have been made in the development of 3D cadmium–zinc–telluride (CZT) detectors operating at room temperature for gamma-ray spectroscopic imaging. This work presents the spectroscopic performance of new high-resolution CZT drift strip detectors, recently developed at IMEM-CNR of Parma (Italy) in collaboration with due2lab (Italy). The detectors (19.4 mm × 19.4 mm × 6 mm) are organized into collecting anode strips (pitch of 1.6 mm) and drift strips (pitch of 0.4 mm) which are negatively biased to optimize electron charge collection. The cathode is divided into strips orthogonal to the anode strips with a pitch of 2 mm. Dedicated pulse processing analysis…

Nuclear and High Energy PhysicsMaterials sciencePhysics::Instrumentation and Detectors030303 biophysics3D CdZnTe detectorsSTRIPS01 natural sciencesElectric chargelaw.invention03 medical and health scienceschemistry.chemical_compounddrift strip detectorslaw0103 physical sciencesInstrumentation0303 health sciencesRadiation010308 nuclear & particles physicsbusiness.industryDetectorElectrostatic inductionSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CathodeCadmium zinc tellurideAnodeFull width at half maximumX-ray and gamma-ray detectorschemistryX-ray and gamma-ray detectors; 3D CdZnTe detectors; drift strip detectors; spectroscopic X-ray and gamma-ray imagingOptoelectronicsbusinessspectroscopic X-ray and gamma-ray imagingJournal of synchrotron radiation
researchProduct

Design of large scale sensors in 180 nm CMOS process modified for radiation tolerance

2019

International audience; The last couple of years have seen the development of Depleted Monolithic Active Pixel Sensors (DMAPS) fabricated with a process modification to increase the radiation tolerance. Two large scale prototypes, Monopix with a column drain synchronous readout, and MALTA with a novel asynchronous architecture, have been fully tested and characterized both in the laboratory and in test beams. This showed that certain aspects have to be improved such as charge collection after irradiation and the output data rate. Some improvements resulting from extensive TCAD simulations were verified on a small test chip, Mini-MALTA. A detailed cluster analysis, using data from laboratory…

Nuclear and High Energy PhysicsOn-chip clusteringPhysics::Instrumentation and Detectors01 natural sciencesCMOS sensors ; Tracking detectors ; Monolithic sensors ; MAPS ; On-chip clustering030218 nuclear medicine & medical imaging03 medical and health sciencesTracking detectors0302 clinical medicinesemiconductor detector: pixelRadiation toleranceCMOS sensors0103 physical sciencesMAPSElectronic engineeringIrradiation[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]numerical calculationsInstrumentationradiation: damagePhysicsPixelirradiation010308 nuclear & particles physicstracking detector: upgradecharge: yieldBandwidth (signal processing)ATLASDigital architectureChipUpgradeAsynchronous communicationMonolithic sensors
researchProduct

Room-Temperature X-ray response of cadmium-zinc-Telluride pixel detectors grown by the vertical Bridgman technique

2020

In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation o…

Nuclear and High Energy PhysicsPhotonMaterials scienceCdZnTe pixel detectorDot pitchCollimated lightCharge sharinglaw.inventionspectroscopic X-ray imagingchemistry.chemical_compoundlawcharge losseInstrumentationRadiationcharge sharingbusiness.industrySettore FIS/01 - Fisica SperimentaleX-raySynchrotronSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Cadmium zinc tellurideFull width at half maximumCdZnTe pixel detectors; charge losses; charge sharing; spectroscopic X-ray imaging; vertical Bridgman technique; X-ray and gamma-ray detectorsX-ray and gamma-ray detectorschemistryOptoelectronicsvertical Bridgman techniquebusinessX-ray and gamma-ray detector
researchProduct

Energy calibration of the NEXT-White detector with 1% resolution near Q ββ of 136Xe

2019

Excellent energy resolution is one of the primary advantages of electroluminescent high pressure xenon TPCs, and searches for rare physics events such as neutrinoless double-beta decay ($\beta\beta0\nu$) require precise energy measurements. Using the NEXT-White detector, developed by the NEXT (Neutrino Experiment with a Xenon TPC) collaboration, we show for the first time that an energy resolution of 1% FWHM can be achieved at 2.6 MeV, establishing the present technology as the one with the best energy resolution of all xenon detectors for $\beta\beta0\nu$ searches.

Nuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsPhysical measurementsPhysics::Instrumentation and DetectorsDark Matter and Double Beta DecayFísica -- Mesuramentschemistry.chemical_elementBioengineeringAtomic01 natural sciencesMathematical SciencesNuclear physicsParticle and Plasma PhysicsXenonAffordable and Clean Energy0103 physical sciencesDark Matter and Double Beta Decay (experiments)CalibrationNuclearlcsh:Nuclear and particle physics. Atomic energy. RadioactivityCalibratge010306 general physicsMathematical PhysicsPhysicsQuantum Physics010308 nuclear & particles physicsDetectorResolution (electron density)MolecularDetectorsNuclear & Particles PhysicsFull width at half maximumchemistryBeta (plasma physics)Physical SciencesCalibrationlcsh:QC770-798High Energy Physics::ExperimentNeutrinoEnergy (signal processing)
researchProduct

Detector characterization and first coincidence tests of a Compton telescope based on LaBr3 crystals and SiPMs

2011

International audience; A Compton telescope for dose monitoring in hadron therapy consisting of several layers of continuous LaBr3 crystals coupled to silicon photomultiplier (SiPM) arrays is under development within the ENVISION project. In order to test the possibility of employing such detectors for the telescope, a detector head consisting of a continuous 16 mm×18 mm×5 mm LaBr3 crystal coupled to a SiPM array has been assembled and characterized, employing the SPIROC1 ASIC as readout electronics. The best energy resolution obtained at 511 keV is 6.5% FWHM and the timing resolution is 3.1 ns FWHM. A position determination method for continuous crystals is being tested, with promising res…

Nuclear and High Energy PhysicsPhysics::Instrumentation and DetectorsCompton telescopeSiPM01 natural sciences7. Clean energyCoincidence030218 nuclear medicine & medical imaginglaw.inventionTelescope03 medical and health sciencesHadron therapy0302 clinical medicineOpticsSilicon photomultiplierApplication-specific integrated circuitlaw0103 physical sciencesCompton imaging[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det][SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsInstrumentationPhysicsContinuous crystal010308 nuclear & particles physicsbusiness.industryResolution (electron density)DetectorMPPCG-APDLaBr3Full width at half maximumbusiness
researchProduct

Development of new CdZnTe detectors for room-temperature high-flux radiation measurements

2017

Recently, CdZnTe (CZT) detectors have been widely proposed and developed for room-temperature X-ray spectroscopy even at high fluxes, and great efforts have been made on both the device and the crystal growth technologies. In this work, the performance of new travelling-heater-method (THM)-grown CZT detectors, recently developed at IMEM-CNR Parma, Italy, is presented. Thick planar detectors (3 mm thick) with gold electroless contacts were realised, with a planar cathode covering the detector surface (4.1 mm × 4.1 mm) and a central anode (2 mm × 2 mm) surrounded by a guard-ring electrode. The detectors, characterized by low leakage currents at room temperature (4.7 nA cm−2 at 1000 V cm−1), a…

Nuclear and High Energy PhysicsPreamplifier02 engineering and technologydigital pulse shape analysiRadiation01 natural scienceslaw.inventionPlanarOpticstravelling heater methodlaw0103 physical scienceshigh fluxInstrumentationenergy-resolved photon-counting detectorsNuclear and High Energy PhysicPhysicsRadiationdigital pulse shape analysis010308 nuclear & particles physicsbusiness.industryCdZnTe detectorsCdZnTe detectorDetectorSettore FIS/01 - Fisica SperimentaleX-ray and γ-ray detectorenergy-resolved photon-counting detector021001 nanoscience & nanotechnologyCathodeSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Anodegold electroless contactFull width at half maximumX-ray and -ray detectors0210 nano-technologybusinessVoltage
researchProduct